Battery Charge at Temperature

Temperature: 7 degrees Fahrenheit Temperature: 67 degrees Fahrenheit
 Percent  Hydrometer  Unloaded  Percent  Hydrometer  Unloaded
charge      reading       voltage charge      reading       voltage
         100         1.242         12.49          100         1.262         12.61
           75         1.187         12.16            75         1.207         12.28
           50         1.137         11.86            50         1.157         11.98
           25         1.097         11.62            25         1.117         11.74
             0         1.077         11.50              0         1.097         11.62
Temperature: 17 degrees Fahrenheit Temperature: 77 degrees Fahrenheit
 Percent  Hydrometer  Unloaded  Percent  Hydrometer  Unloaded
charge      reading       voltage charge      reading       voltage
         100         1.245         12.51          100         1.265         12.63
           75         1.190         12.18            75         1.210         12.30
           50         1.140         11.88            50         1.160         12.00
           25         1.100         11.64            25         1.120         11.76
             0         1.080         11.52              0         1.100         11.64
Temperature: 27 degrees Fahrenheit Temperature: 87 degrees Fahrenheit
 Percent  Hydrometer  Unloaded  Percent  Hydrometer  Unloaded
charge      reading       voltage charge      reading       voltage
         100         1.248         12.53          100         1.268         12.65
           75         1.193         12.20            75         1.213         12.32
           50         1.143         11.90            50         1.163         12.02
           25         1.103         11.66            25         1.123         11.78
             0         1.083         11.54              0         1.103         11.66
Temperature: 37 degrees Fahrenheit Temperature: 97 degrees Fahrenheit
 Percent  Hydrometer  Unloaded  Percent  Hydrometer  Unloaded
charge      reading       voltage charge      reading       voltage
         100         1.252         12.55          100         1.272         12.67
           75         1.197         12.22            75         1.217         12.34
           50         1.147         11.92            50         1.167         12.04
           25         1.107         11.68            25         1.127         11.80
            0          1.087         11.56              0         1.107         11.68
Temperature: 47 degrees Fahrenheit Temperature: 107 degrees Fahrenheit
 Percent  Hydrometer  Unloaded  Percent  Hydrometer  Unloaded
charge      reading       voltage charge      reading       voltage
         100         1.255         12.57          100         1.275         12.69
           75         1.200         12.24            75         1.220         12.36
           50         1.150         11.94            50         1.170         12.06
           25         1.110         11.70            25         1.130         11.82
             0         1.090         11.58              0         1.110         11.70
Temperature: 57 degrees Fahrenheit
 Percent  Hydrometer  Unloaded
charge      reading       voltage
         100         1.258         12.59
           75         1.203         12.26
           50         1.153         11.96
           25         1.113         11.72
             0         1.093         11.60

Battery Charge at Temperature